Abstract
Walking tests, such as the "shuttle" incremental walking test (SWT) and the 6-min walking test (6'WT), are commonly utilized in evaluating exercise intolerance in patients with chronic obstructive pulmonary disease (COPD) and the distance covered is the variable usually considered. Because lung gas exchange indexes are not measured, little is known about the physiological response elicited by different walking protocols. We compared exercise adaptation during the 6'WT and SWT in 13 male stable COPD patients [mean (SE) age: 70 (1) years; forced expiratory volume in 1 s (FEV1): 1.2 (0.1) l; arterial O2 tension (PaO2): 72 (2) mmHg; arterial CO2 tension (PaCO2): 41 (1) mmHg]. Oxygen uptake (V̇O2), CO2 output (V̇CO2), minute ventilation (V̇ E), and heart rate (HR) were monitored by a portable telemetric system. During the SWT a linear response in lung gas exchange indexes was observed while, during the 6'WT, the response was exponential. During the 6'WT, V̇O2, V̇CO2, V̇ E, and HR values at steady-state (SS) were significantly lower compared to SWT peak values. For SWT, distance covered correlated with V̇O2PEAK (R=0.86, p<0.001), V̇CO2PEAK (R=0.87, p<0.001) and V̇ EPEAK (R=0.74, p<0.01); moreover, distance and V̇O2PEAK were significantly correlated with peak V̇O2 values obtained during cycle ergometer incremental exercise (R=0.72, p<0.01 and R=0.92, p<0.0001, respectively). For 6'WT, the distance covered did not correlate with any pertinent physiological index. The two walking protocols reveal substantial differences in pathophysiologic adaptations and provide evidence that SWT is more accurate than the 6'WT in the evaluation of maximal exercise tolerance in COPD patients.
Similar content being viewed by others
References
Baarends EM, Schols AM, Mostert R, Janssen PP, Wouters EF (1998) Analysis of the metabolic and ventilatory response to self-paced 12-minute treadmill walking in patients with severe chronic obstructive pulmonary disease. J Cardiopulm Rehabil 18:23–31
Bauerle O, Younes M (1995) Role of ventilation response to exercise in determining exercise capacity in COPD. J Appl Physiol 79:1870–1877
Beaver WL, Wasserman K, Whipp BJ (1973) On-line computer analysis and breath-by-breath graphical display of exercise function tests. J Appl Physiol 34:128–132
Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurements. Lancet 1:307–310
Butland RJA, Gross ER, Pang J, Gross ER, Woodcock AA, Geddes DM (1982) Two-, six-, and 12-minute walking tests in respiratory diseases. Br Med J 284:1607–1608
Dejour P (1964) Control of respiration in muscular exercise. In: Handbook of physiology: respiration. Section 3, chapter 25. American Physiological Society, Washington DC, pp 631–638
Dyer CA, Singh SJ, Stockley RA, Sinclair AJ, Hill SL (2002) The incremental shuttle walking test in elderly people with chronic airflow limitation. Thorax 57(1):34–38
ERS Task Force on Standardization of Clinical Exercise Testing (1997) Clinical exercise testing with reference to lung disease: indications, standardization and interpretation strategies. Eur Respir J 10:2662–2689
Global Initiative for Chronic Obstructive Lung Disease. NHLBI/WHO workshop report. NIH Publication No. 2701. April 2001
Green DJ, Watts K, Rankin S, Wong P, O'Driscoll JG (2001) A comparison of the shuttle and 6 minute walking tests with measured peak oxygen consumption in patients with heart failure. J Sci Med Sport 4(3):292–300
Guyatt GH, Pugsley SO, Sullivan MJ, Thompson PJ, Berman LB, Jones NL (1984) Effect of encouragement on walking test performance. Thorax 39:818–822
Guyatt GH, Sullivan MJ, Thompson PJ, Fallen EL, Pugsley SO, Taylor DW, Berman LB (1985) The 6-minute walk: a new measure of exercise capacity in patient with chronic heart failure. Can Med Assoc J 132:919–923
Léger LA, Lambert J (1982) A maximal multistage 20-m shuttle run test to predict V̇O2max. Eur J Appl Physiol 49:1–12
McLaughlin JE, King GA, Howley ET, Bassett DR Jr, Ainsworth BE (2001) Validation of the Cosmed K4b2 portable metabolic system. Int J Sports Med 22:280–284
Morales FJ, Martìnez A, Méndez M, Agarrado A, Ortega F, Fernàndez-Guerra J, Montemayor T, Burgos J (1999) A shuttle walk test for assessment of functional capacity in chronic heart failure. Am Heart J 138:291–298
Palange P, Forte S, Onorati P, Manfredi F, Serra P, Carlone S (2000) Ventilatory and metabolic adaptations to walking and cycling in patients with COPD. J Appl Physiol 88:1715–1720
Singh SJ, Morgan MDL, Scott S, Walters D, Hardman AE (1992) Development of a shuttle walking test of disability in patients with chronic airways obstruction. Thorax 47:1019–1024
Singh SJ, Morgan MDL, Hardman AE, Rowe C, Bardsley PA (1994) Comparison of oxygen uptake during a conventional treadmill test and the shuttle walking test in chronic airflow limitation. Eur Respir J 7:2016–2020
Spiro SG (1977) Exercise testing in clinical medicine. Br J Dis Chest 71:145–172
Wilmore DW (1997) The metabolic management of the critically ill. Plenum, New York, p 16
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Onorati, P., Antonucci, R., Valli, G. et al. Non-invasive evaluation of gas exchange during a shuttle walking test vs. a 6-min walking test to assess exercise tolerance in COPD patients. Eur J Appl Physiol 89, 331–336 (2003). https://doi.org/10.1007/s00421-003-0803-9
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00421-003-0803-9