Abstract
Background Thoracentesis and thoracoscopy are used to diagnose malignant pleural effusions (MPE). Data on how sensitivity varies with tumour type is limited.
Methods Systematic review using PubMed was performed through August 2020 to determine the sensitivity of thoracentesis and thoracoscopy for MPE secondary to malignancy, by cancer type, and complication rates. Tests to identify sources of heterogeneity were performed. Study quality was assessed using Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 and National Institutes of Health quality assessment tools. Publication bias was tested using funnel plots.
Results Meta-analyses for sensitivity of thoracentesis for MPE secondary to malignancy, mesothelioma and lung and breast cancer included 29, eight, 12 and nine studies, respectively. Pooled sensitivities were 0.643 (95% CI 0.592–0.692), 0.451 (95% CI 0.249–0.661), 0.738 (95% CI 0.659–0.836) and 0.820 (95% CI 0.700–0.917), respectively. For sensitivity of thoracoscopy for MPE secondary to malignancy and mesothelioma, 41 and 15 studies were included, respectively. Pooled sensitivities were 0.929 (95% CI 0.905–0.95) and 0.915 (95% CI 0.871–0.952), respectively. Pooled complication rates of thoracentesis and thoracoscopy were 0.041 (95% CI 0.025–0.051) and 0.040 (95% CI 0.029–0.052), respectively. Heterogeneity was significant for all meta-analyses. Funnel plots were asymmetric.
Interpretation Sensitivity of thoracentesis varied significantly per cancer type. Pooled complication rates were low. Awareness of how sensitivity of thoracentesis changes across cancers can improve decision-making when MPE is suspected.
Abstract
Sensitivity of thoracentesis varies significantly per cancer type. Awareness of how sensitivity of thoracentesis changes across cancer types can improve decision-making in patients with suspected malignant pleural effusion. https://bit.ly/3bEiPYq
Introduction
Approximately 15% of patients with malignancy have malignant pleural effusion (MPE) [1, 2]. Currently, procedures to diagnose MPE include thoracentesis with pleural fluid cytology and thoracoscopy with pleural biopsy; the latter is often used as gold standard [3]. Accurate estimates of sensitivity of thoracoscopy and thoracentesis are clinically important because test sensitivity and complication rates drive decision-making on how to best manage MPEs [4].
We undertook this meta-analysis as part of a project to create a decision analysis model for diagnosis of MPE. Estimates of the sensitivity of thoracentesis and thoracoscopy for MPE by cancer type and complication rates were required. During the decision analysis process, we found that no meta-analysis had been published reporting the pooled sensitivity of thoracentesis for MPE [5]. Instead, the British Thoracic Society guidelines provide a mean sensitivity of thoracentesis for MPE for any malignancy of 0.6 (range 0.4–0.87) based on an analysis of four studies [6–9]. However, recent studies have shown that sensitivity of thoracentesis varies significantly between tumour types [10, 11]. For effective decision analysis, more rigorous estimates of the pooled sensitivity of thoracentesis are required, ideally stratified by cancer type.
Regarding thoracoscopy, a recent meta-analysis by Wei et al. [12] reported a pooled sensitivity of thoracoscopy for exudative pleural effusions, but did not report a pooled sensitivity for MPE and did not report sensitivity by cancer type. Instead, diagnostic accuracy of thoracoscopy for MPE and mesothelioma was reported [12]. Thus, we decided to perform meta-analyses on thoracentesis and thoracoscopy to provide updated estimates of their sensitivity for MPE stratified by cancer type when possible.
The primary objective of this study was to obtain a pooled sensitivity of thoracentesis and thoracoscopy for MPE due to any malignancy. Secondary analyses were performed to determine thoracentesis and thoracoscopy sensitivity for the following specific types of cancer: mesothelioma, lung cancer and breast cancer. Secondary objectives were to obtain the pooled complication rate of thoracentesis and thoracoscopy and the pooled pneumothorax rate of thoracentesis.
Methods
Literature search and study selection
We performed a systematic review and meta-analysis of thoracentesis and thoracoscopy following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis diagnostic test accuracy guidelines [13]. We pre-specified that a total of 161 studies (71 for thoracentesis and 90 for thoracoscopy; figure 1) included in the quantitative review have a sample size ≥10 patients with pleural effusions ultimately shown to be due to malignancy. We also pre-specified that only studies reporting results for ultrasound-guided thoracentesis with either diagnostic or both diagnostic and therapeutic purposes would be considered for pooled complication rate calculations. We specified that medical thoracoscopy, pleuroscopy and video-assisted thoracoscopic surgery would be grouped as one procedure type. Studies that used a substantially different technique (e.g. fibreoptic bronchoscope instead of a thoracoscope) were excluded. Only randomised controlled studies (RCTs) and cohort studies published in English were considered. Reviews, letters to the editor, abstracts, meta-analysis, case reports and studies without the full text available were excluded.
Searches were performed in July 2020 using the electronic MEDLINE database (PubMed) for sensitivity and complications of thoracentesis and thoracoscopy (supplementary table E1). A manual search of references cited in original investigations and review papers and cross-referencing was performed, to ensure that all articles were captured.
Two authors, S. Molina and G. Martinez-Zayas, independently and blindly performed the search strategies and screened the articles based on the inclusion and exclusion criteria described. The studies were first screened by title and then by abstract. Discordance was resolved by discussion and further review of the papers. Studies were selected for inclusion only after both reviewers assessed the full text.
Data extraction
S. Molina and G. Martinez-Zayas independently abstracted each study and then compared results of their data abstraction. In cases where there was discordance, further review was performed.
For studies reporting sensitivity, data was abstracted to record true positives, false positives, true negatives and false negatives. All thoracentesis cytology results that revealed cancer were considered true positives. Similarly, all thoracoscopy biopsies that revealed cancer were considered true positives. The reference standard of truth used to define false-negative results was recorded as well. For all studies, when patients were found to have MPE, the sensitivity stratified by cancer type was also recorded if information was available.
For studies reporting complications of thoracentesis, the types of complications were recorded. We specified that inadequate sampling, transient cough and mild chest pain would not be considered as complications. All other complications were grouped together as the complication rate. When specified, the frequency of pneumothorax was recorded separately. Because pneumothorax can occur after thoracentesis, but does not tend to do so immediately after thoracoscopy, and patients usually have chest tube placement after thoracoscopy, we conducted an exploratory analysis of thoracentesis complications other than pneumothorax. The thoracentesis complication rate excluding pneumothorax was used to facilitate comparison of complication rates between thoracentesis and thoracoscopy.
For studies on thoracoscopy, we specified that peri-procedural hypotension and respiratory difficulty, pain, dislodged drains, inadequate sampling, post-procedure fever that resolved in <72 h, additional chest tube use and minor bleeding would not be included as complications. The frequency of all other complications were grouped together as the complication rate.
Risk of bias within studies and study quality assessment
For studies reporting sensitivity of thoracoscopy or thoracentesis, assessment of within study bias was done using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 instrument (supplementary material) [14]. Studies were independently assessed by G. Martinez-Zayas and S. Molina. Results were compared and consensus was reached after discussion with adjudication by a third reviewer as needed. Because the QUADAS-2 tool can only be used for diagnostic studies, the National Institutes of Health (NIH) quality assessment tool was used for studies reporting complications [14, 15]. This tool can be used both for RCTs and observational studies (supplementary material).
If a study reported only sensitivity, we used QUADAS-2. If only complication rates were reported, we only used the NIH quality assessment tool. Finally, if both sensitivity and complication rates were reported, we used both tools.
Summary measures
The primary objective was to determine the sensitivity of thoracentesis and thoracoscopy for MPE due to any malignancy, defined as true positives/(true positives+false negatives). Secondary objectives included determining the complication and pneumothorax rates of thoracentesis, and complication rate of thoracoscopy.
For meta-analyses on sensitivity, extracted data were pooled using weighted averages based on the inverse of the variance. The 95% confidence intervals were calculated using the exact binomial method and the Freeman–Tukey double arcsine transformation of proportions using the “metaprop” command in Stata [16]. We used the “midas” command in Stata to generate summary receiver operating characteristic curves (sROCs) [17, 18]. Sensitivities were calculated per patient.
Given that many studies had zero complications, for meta-analyses on complications or pneumothorax we calculated the pooled estimate of the complication rate and pneumothorax rate after Freeman–Tukey double arcsine transformation and used the score statistic for determining confidence intervals. Complication rates were calculated per procedure.
For all statistical tests, we chose an α=0.05.
Synthesis of results
For all pooled estimate calculations, we expected to find significant heterogeneity, so random-effects models were used. We assessed heterogeneity using the I2 statistic and the heterogeneity Chi-squared. The I2 statistic describes the percentage of total variation across studies due to heterogeneity between studies rather than chance. A value >75% is considered as major heterogeneity and a value <40% is considered insufficient to prove heterogeneity [19]. For heterogeneity Chi, the null hypothesis is that there is no heterogeneity, therefore p<0.05 rejects the null hypothesis of no heterogeneity.
Causes of heterogeneity between studies were evaluated using stratified analysis for categorical variables and meta-regression for continuous variables. Pre-specified subgroups included year of study publication and prevalence of MPE. For studies on thoracoscopy, additional subgroups were type of thoracoscope (rigid versus semi-rigid versus mixed) and type of anaesthesia (general versus local with moderate sedation).
Publication bias and sample-size effects
We used funnel plot asymmetry to identify publication bias. For our primary analysis, we used funnel plots of sample size using a logarithmic scale versus the logit of sensitivity, based on previous work that suggests that this is better than standard funnel plots for meta-analysis of proportions [20]. Secondary analysis was done using standard funnel plots, plotting the inverse of standard error versus the logit of sensitivity. We used both the Egger and Begg tests to assess for publication bias, acknowledging that both tests have limitations and can produce different results [21–23]. We used the same methods for analysis of complication rates.
In addition, for meta-analyses on sensitivity we adjusted for publication bias using the “metatrim” command in Stata. This command uses the nonparametric trim and fill method proposed by Duval and Tweedie [24]. This method provides a revised pooled sensitivity after incorporating theoretical missing studies in the meta-analysis.
Outlier analysis
We pre-specified that if significant heterogeneity in meta-analyses for sensitivity was identified, a secondary analysis would be performed after removing outliers. Outliers were identified using Cook's distance and a scatter plot of the standardised predicted random effects (supplementary material, methods section).
All statistical analysis was performed using Stata version 15.1 (StataCorp LLC, College Station, TX, USA).
Results
Thoracentesis: study selection and characteristics
After screening, 71 studies were included in the meta-analysis of sensitivity and complications of thoracentesis (figure 1a). Out of the 71 studies, 32 reported results for sensitivity, 38 for complications, and one for both sensitivity and complications. Two studies [25, 26] were RCTs (supplementary tables E2 and E3).
Thoracentesis: risk of bias within studies and study quality assessment
For sensitivity, included studies had a low risk of bias in terms of the index test and selection criteria and study applicability was good (supplementary figure E1, supplementary table E4). The most frequently used reference standards were thoracoscopy, closed pleural biopsy, thoracotomy and clinical-radiographic surveillance. Only negative results by thoracentesis were compared to the reference standard (i.e. specificity was assumed to be 100%). For complications, most included studies were considered high or fair quality (supplementary figure E2, supplementary table E5).
Thoracentesis: results of individual studies and synthesis of results
Pooled sensitivities are shown in table 1. 29 studies (5444 patients) were included in the meta-analysis for sensitivity of thoracentesis for MPE secondary to any malignancy (figure 2). The pooled sensitivity was 0.643 (95% CI 0.59–0.692).
In stratified analyses, eight studies (1133 patients) were included in the meta-analysis for sensitivity for MPE secondary to mesothelioma (figure 3a). The pooled sensitivity was 0.451 (95% CI 0.249–0.661). Stratified analysis of sensitivity for MPE secondary to lung cancer included 12 studies (1184 patients). The pooled sensitivity was 0.752 (95% CI 0.659–0.836; figure 3b). Finally, stratified analysis of sensitivity for MPE secondary to breast cancer included eight studies (532 patients). The pooled sensitivity was 0.820 (95% CI 0.700–0.917; figure 3c). For all meta-analyses, heterogeneity was significant (table 1) and the sROCs are shown in supplementary figure E3. We failed to find an association between sensitivity and year of publication or cancer prevalence (table 1).
Complications included pneumothorax, re-expansion pulmonary oedema and haemothorax, among others (supplementary table E6). 23 studies were included in the meta-analyses for complication rate. The pooled complication rate was 0.041 (95% CI 0.025–0.061; supplementary figure E4). Similarly, 36 studies were included in the meta-analyses for pneumothorax rate. The pooled estimate was 0.025 (95% CI 0.017–0.034; supplementary figure E5A). Finally, the pooled estimate of complications other than pneumothorax (supplementary table E6) was 0.015 (95% CI 0.009–0.023; supplementary figure E5B). Heterogeneity was significant in all meta-analyses (table 1). We failed to find an association between complication rate and year of publication or cancer prevalence (table 1).
Thoracentesis: publication bias and sample size effects
Funnel plots demonstrated asymmetry across studies that reported the sensitivity of thoracentesis for MPE secondary to any malignancy (supplementary figure E6). Interestingly, funnel plots seemed to suggest that small studies reporting high sensitivity were less likely to be published than small studies with low sensitivity. After trim and fill, the bias-adjusted pooled sensitivity of thoracentesis was 0.63 (95% CI 0.582–0.676; supplementary figure E7, supplementary table E7). Funnel plots for complication and pneumothorax rates are discussed in the supplementary material, results section.
The Begg and Egger tests for publication bias were nonsignificant (p=0.561 and p=0.374, respectively; supplementary table E8). There were too few studies in the stratified analyses to perform meaningful funnel plot analysis and the Begg and Egger tests. Begg and Egger test for complication and pneumothorax rates are discussed in the supplementary material, results section.
Thoracentesis: outlier analysis
The outlier analysis identified six [9, 27–31] outliers. Removing them did not significantly change the pooled sensitivity for any malignancy, within strata heterogeneity p-value or I2 (supplementary figure E8, supplementary table E9). Funnel plot asymmetry and significance of the Begg and Egger tests did not change either (supplementary figure E8 and supplementary table E8). For the stratified analysis, removing one [11] identified outlier did not significantly change the pooled sensitivity for mesothelioma, heterogeneity p-value or I2 (supplementary figure E10, supplementary table E9). No outliers were identified for lung or breast cancer.
Thoracoscopy: study selection and characteristics
90 studies were included in the meta-analysis for complications and sensitivity of thoracoscopy (figure 1b). Out of the 90 studies, 11 reported results for sensitivity, 47 for complications and 32 for both sensitivity and complications. There was variation on the type of thoracoscope used across studies (supplementary table E10 and E11). Seven studies [32–38] were RCTs.
Thoracoscopy: risk of bias within studies and study quality assessment
For sensitivity, included studies had a low risk of bias in terms of the index test and selection criteria and study applicability was good (supplementary figure E1, supplementary table E12). The most frequently used reference standards were thoracotomy, computed tomography guided biopsy, autopsy, repeat thoracoscopy and clinical-radiographic follow-up. Except for two studies [39, 40], only negative results were compared to the reference standard (i.e. specificity was assumed to be 100%). For complications, most included studies were considered high or fair quality (supplementary figure E2, supplementary table E13).
Thoracoscopy: results of individual studies and synthesis of results
41 studies (2963 patients) were included in the meta-analysis for sensitivity for MPE due to any malignancy. The pooled sensitivity was 0.929 (95% CI 0.905–0.95; figure 4). In the stratified analysis, 15 studies (453 patients) were included in the meta-analysis for sensitivity for MPE secondary to mesothelioma. The pooled sensitivity was 0.915 (95% CI 0.871–0.952; figure 5). Heterogeneity was significant in both meta-analyses (table 2) and the sROCs are shown in supplementary figure E11. Only one study provided stratified results for lung cancer and no studies reported stratified results for breast cancer, so meta-analyses were not performed. We failed to find an association between potential causes of heterogeneity and the sensitivity of thoracoscopy (table 2).
Examples of complications of thoracoscopy that were included are persistent fluid leakage after 24 h, trapped lung and re-expansion pulmonary oedema among others (supplementary table E6). 79 studies were included in the meta-analysis for complication rate of thoracoscopy. The pooled complication rate was 0.040 (95% CI 0.029–0.052; supplementary figure E12). Heterogeneity was significant (table 2). We failed to find an association between potential causes of heterogeneity and the complication rate of thoracoscopy (table 2).
Thoracoscopy: publication bias and sample size effects
We observed funnel plot asymmetry for sensitivity for any malignancy, with plots suggesting that smaller studies with lower sensitivities were less likely to be published (supplementary figure E13). The Begg and Egger tests results were nonsignificant (p=0.545 and p=0.061, respectively; supplementary table E8). After trim and fill, the bias adjusted pooled sensitivity of thoracoscopy for MPE secondary to any malignancy decreased to 0.889 (95% CI 0.86–0.91; supplementary figure E14). There were too few studies in the stratified analyses to perform meaningful funnel plot analysis or for the Begg and Egger tests. Funnel plots, Begg and Egger tests for complication rates of thoracoscopy are discussed in the supplementary material results section.
Thoracoscopy: outlier analysis
Outlier analysis identified two [41, 42] outliers. Removing them did not significantly modify the pooled sensitivity for any malignancy, within strata heterogeneity p-value or the I2 (supplementary figure E15, supplementary table E9). Funnel plot asymmetry and significance of the Begg test did not change either (supplementary figure E16 and supplementary table E8, respectively). However, the Egger test became significant (p=0.016), suggesting that removing the outlier introduced publication bias.
For the stratified analysis, removing one [43] identified outlier slightly modified the pooled sensitivity for mesothelioma but changed significance of the heterogeneity p-value, and I2 (supplementary figure E17, supplementary table E9). The Begg and Egger tests were not performed for the stratified analysis, so modification after removing outliers was not assessed.
Discussion
In this meta-analysis, we report the pooled sensitivities of thoracentesis and thoracoscopy for MPE secondary to any type of malignancy and per cancer type, as well as the pooled complication rates of thoracentesis and thoracoscopy, and pneumothorax rate of thoracentesis. The pooled sensitivities of thoracentesis for MPE secondary to any malignancy, mesothelioma, lung cancer and breast cancer were 0.643 (95% CI 0.592–0.692), 0.451 (95% CI 0.249–0.661), 0.738 (95% CI 0.659–0.836) and 0.820 (95% CI 0.700–0.917), respectively. The pooled sensitivities of thoracoscopy for MPE secondary to any malignancy and mesothelioma were 0.929 (95% CI 0.905–0.95) and 0.915 (95% CI 0.871–0.952), respectively. The pooled complication rate of thoracentesis was 0.041 (95% CI 0.025–0.051). The pooled pneumothorax rate was 0.025 (95% CI 0.017–0.034). Finally, the pooled complication rate of thoracoscopy was 0.040 (95% CI 0.029–0.052).
To our knowledge, this is the largest meta-analysis on sensitivity of thoracentesis. Various studies have reported the combined sensitivity of thoracentesis for MPE [6–8, 44, 45], but a meta-analysis reporting the pooled sensitivity of thoracentesis for MPE stratified per cancer type has not been reported. More recently, studies have reported the sensitivity of thoracentesis for MPE varies according to tumour type [10, 11]. For instance, Grosu et al. [10] reported that the sensitivity of thoracentesis for MPE secondary to mesothelioma and breast cancer were 0.0 (95% CI 0.0–0.7) and 0.93 (95% CI 0.88–0.97), respectively. Similarly, the sensitivity of thoracentesis for lung cancer was stratified per lung cancer histology, with sensitivities ranging from 0.69 (95% CI 0.39–0.90) to 0.92 (95% CI 0.78–0.98), depending on lung cancer histology [10]. Arnold et al. [11] reported sensitivities of 0.06 (95% CI 0.028–0.11), 0.56 (95% CI 0.48–0.637) and 0.707 (95% CI 0.57–0.82) for mesothelioma, lung cancer and breast cancer, respectively. However, both studies were single-centre studies with relatively modest sample sizes (mesothelioma n=5 and n=148, lung cancer n=158 and n=166 and breast cancer n=165 and n=58, respectively). This meta-analysis builds on and extends their observations by pooling data from many studies. The resulting sample size is much larger (mesothelioma n=8565, n=1133 included in sensitivity analysis; lung cancer n=6267, n=1184 included in the sensitivity analysis; and breast cancer n=5620, n=532 included in the sensitivity analysis) and is drawn from a wide range of institutions.
Knowledge of strata-specific sensitivities of thoracentesis for MPE by cancer type adds to the existing body of knowledge because it can be used to tailor the diagnostic approach to individual patients. For example, older guidelines suggested repeating thoracentesis up to three times before progressing to thoracoscopy in patients with suspected MPE [46, 47]. Recent guidelines suggest performing one thoracentesis, and if nondiagnostic to progress directly to thoracoscopy [6, 48, 49]. However, both old and new guidelines did not consider that the sensitivity of thoracentesis varies by cancer type. Here, we confirmed the findings of prior studies that the sensitivity of thoracentesis for MPE is indeed very low for mesothelioma. In addition, by pooling the results from many studies, we were able to confirm the preliminary findings of Grosu et al. [10] and Arnold et al. [11] that sensitivity of thoracentesis varies significantly for other cancer types, being intermediate for lung cancer and high for breast cancer. Our study suggests that rather than a one-size-fits-all approach to patients with suspected MPE, a more nuanced approach is warranted. For instance, in patients with high pre-test probability of mesothelioma (e.g. asbestos exposure, chest pain, pleural plaques and thickening) presenting with a pleural effusion, proceeding directly to thoracoscopy is reasonable given the low sensitivity of thoracentesis for mesothelioma and relatively low complication rate of thoracoscopy [50]. Conversely, in a patient with known breast cancer presenting with a large pleural effusion without evidence of infection or heart failure, chances are that the effusion is secondary to breast cancer. In this case, given the high sensitivity of thoracentesis for breast cancer MPE and because thoracentesis is less invasive than thoracoscopy, two or more thoracenteses might be warranted prior to proceeding to thoracoscopy. For patients with known lung cancer presenting with a large pleural effusion, moderate sensitivity of thoracentesis suggests that consistent with current guidelines, a single thoracentesis may be worthwhile, and if that is nondiagnostic proceeding to thoracoscopy would be an appropriate next step. Decision-making could be further guided if the histology of the lung cancer is known [10].
Regarding complications of thoracentesis, the most recent meta-analysis in 2010 by Gordon et al. [51] reported a pooled pneumothorax rate slightly higher than ours (0.04, 95% CI 0.029–0.056), but had fewer studies (n=16) and included studies that did not use ultrasound guidance. Ultrasound guidance for thoracentesis is now standard, so we limited our meta-analysis to studies using ultrasound so that our estimate of pneumothorax rates and complications would be more applicable to current practice.
In addition, our study is the first meta-analysis to report the pooled sensitivity of thoracoscopy. A recent meta-analysis by Wei et al. [12] calculated the pooled sensitivity of thoracoscopy for exudative pleural effusions in 1783 patients. However, all aetiologies of exudative effusions (i.e. cancer and infection) were grouped together and not stratified by cancer type. Their study did report the diagnostic accuracy of thoracoscopy for MPE secondary to any malignancy (0.92, 95% CI 0.88–0.95) and mesothelioma (0.42, 95% CI 0.22–0.62%), but did not report sensitivities. Another meta-analysis evaluating the sensitivity of thoracoscopy for exudative effusions identified 17 studies in the literature through 2013 [52]. It reported a pooled sensitivity of 0.91 (95% CI 0.89–0.93) [52]. This meta-analysis was also for exudative pleural effusions and grouped all aetiologies together without stratifying by cancer type.
Finally, regarding complications of thoracoscopy, Wei et al. [12] reported a complication rate higher than ours (0.08, 95% CI, 0.06–0.11), probably because they included all complications reported in all studies when calculating their pooled estimate. But different studies used different definitions of what constituted a complication, including some that are not broadly recognised as complications (e.g. inadequate sample) and some that are generally considered as unavoidable (e.g. pain). A list of the types of complications they counted was not provided. To address the issue of varying definitions, we compared the complications listed in different studies at a granular level, eliminating those complications that were not consistently reported and those that were nonstandard (supplementary table E6).
There are multiple causes of funnel plot asymmetry such as publication bias, under-publication of negative studies, conflicts of interest, inadequate design and analysis, among others [53–55]. When publication bias is related to size effects, the small studies reporting lower sensitivities are missing from the funnel plots [56–58], as observed in our funnel plots for sensitivity of thoracoscopy. However, our funnel plots for thoracentesis showed that small studies reporting larger sensitivities seemed more likely to be missing, suggesting the presence of sample size effects unrelated to publication bias. In other words, the asymmetry observed in our funnel plots could be related to other unassessed causes [53–55]. Note that we failed to find significance in the Begg and Egger tests. However, for small meta-analyses such as those used in typical medical research (and in our study, publication), bias should not be ruled out when the tests are not significant [22, 23, 55].
It is important to be cognisant of the limitations of our study. First, we failed to obtain sufficient studies reporting sensitivity of thoracoscopy for MPE secondary to lung or breast cancer and therefore could not obtain cancer-specific sensitivities for thoracoscopy. Another limitation is that very few studies [9–11, 59] reported sensitivities of thoracentesis for MPE secondary to malignancies other than mesothelioma, lung or breast cancer. While our approach highlights the potential for a more individualised approach to the evaluation of pleural effusion, additional data on thoracentesis sensitivity for many other cancer types are required. It is also important to acknowledge that most of the studies included in the meta-analyses for sensitivity for mesothelioma were published before studies reporting that BAP1 immunostaining and CDKN2A increased sensitivity for mesothelioma were published [60, 61]. Therefore, in future with more studies using BAP1 and CDKN2A, the pooled sensitivities for mesothelioma may vary. Similarly, we did not perform a subgroup analysis for sensitivity of thoracentesis for mesothelioma using cell block techniques, which have been reported to increase the pooled sensitivity for mesothelioma [62] and other metastatic cancers [63]. Unfortunately, much of the literature does not specify sensitivity according to whether cell blocks were used in individual cases, so a more refined subgroup analysis is not possible at this time. This type of subgroup analysis can be addressed in future studies. Finally, there was significant heterogeneity between studies; however, the relatively low number of studies limited our ability to identify factors that might be explain the observed heterogeneity. Therefore, the stratified results and meta-regression analysis should be viewed as exploratory. It is possible differences in the frequency of various cancer types between studies (e.g. Grosu et al. [10] versus Arnold et al. [11]) could account for the observed heterogeneity, but the data in the original reports do not permit a more detailed analysis.
In conclusion, we found a pooled sensitivity of thoracentesis for malignancy of 0.643 and a pooled sensitivity of thoracoscopy for malignancy of 0.929, although there was significant heterogeneity between studies. Sensitivity of thoracentesis was lowest for mesothelioma, intermediate for lung cancer and highest for breast cancer. Pooled complication rates for both procedures were low. Awareness of how sensitivity of thoracentesis varies across different cancer types can inform decision making in patients with suspected MPE, allowing physicians to individualise diagnostic strategy in a more effective manner.
Supplementary material
Supplementary Material
Please note: supplementary material is not edited by the Editorial Office, and is uploaded as it has been supplied by the author.
Supplementary material ERR-0053-2022.SUPPLEMENT
Footnotes
Provenance: Submitted article, peer reviewed.
Conflicts of interest: G. Martinez-Zayas, S. Molina and D.E. Ost have no conflicts of interest to disclose and take full responsibility for this paper.
- Received April 2, 2022.
- Accepted July 31, 2022.
- Copyright ©The authors 2022
This version is distributed under the terms of the Creative Commons Attribution Non-Commercial Licence 4.0. For commercial reproduction rights and permissions contact permissions{at}ersnet.org